storage tank design code

Storage Tank Design Code: Expert Tips & Regulations

By Richard Jackson
AD

Designing storage tanks is a critical process that requires adherence to stringent codes and standards to ensure safety, efficiency, and longevity. These structures serve pivotal roles in various industries, including oil and gas, chemical processing, and water treatment, among others. Therefore, understanding and applying storage tank design codes is paramount for engineers and project managers.

The design of storage tanks is governed by several international and regional codes and standards. The three most widely recognized are the API (American Petroleum Institute) standards, theKennedy-Hanawalt (K-H) formula, and the European standard EN 14015. Each code offers unique insights and guidelines, but all aim to provide a robust, reliable, and cost-effective design.

API Storage Tank Standards

The API has developed a series of standards, namely API 620, API 650, and API 653, which are widely adopted in the petroleum industry. These standards provide design, construction, and maintenance guidelines for atmospheric and low-pressure storage tanks.

AD
Detailed Engineering of Storage Tanks - Musandam Gas Plant
Detailed Engineering of Storage Tanks - Musandam Gas Plant
some blueprints showing different types of furniture
some blueprints showing different types of furniture
types of Storage tank
types of Storage tank

API 620, for instance, addresses the design and construction of large, welded, low-pressure storage tanks with nominal capacities exceeding 1,000 barrels. API 650, on the other hand, covers the design and fabrication of welded, low-pressure, atmospheric storage tanks with capacities up to 300,000 barrels. API 653, meanwhile, focuses on the maintenance, repair, alteration, and reinstallation of aboveground storage tanks.

API Design Considerations

API standards consider multiple factors in the design process, including tank geometry, materials of construction, pressure, and temperature. Additional design considerations include wind and snow loads, seismicity, and the potential for atmospheric corrosion.

Oil Storage Tank Foundation Design Spreadsheet
Oil Storage Tank Foundation Design Spreadsheet
Storage Tank Types: Choosing the Right One for Your Facility | Tayib A. posted on the topic | LinkedIn
Storage Tank Types: Choosing the Right One for Your Facility | Tayib A. posted on the topic | LinkedIn
an image of storage tanks labeled in different languages
an image of storage tanks labeled in different languages

API 620 and 650 provide methodologies for determining minimum shell plate thickness, bottom plate thickness, and reinforcing plate thickness. These calculations ensure the structure can withstand the intended design loads without exceeding the yield or tensile strength of the materials employed.

API Tank Design: Putting It Into Practice

When applying API standards, engineers start by determining the tank's profile, which is defined by the tank's aspect ratio (shell diameter to height ratio). The profile influences the tank's stability and resistance to wind and snow loads.

AD

The selection of materials is also crucial. API standards recommend using steel grades that provide the necessary strength and corrosion resistance. After determining the tank's dimensions and material, the design process involves calculating the required plate thicknesses, supervisor the vessel fabrication, and inspecting the completed tank.

Storage Tank Foundation Design Guide pdf download
Storage Tank Foundation Design Guide pdf download
the tank diagram shows how it works
the tank diagram shows how it works
Tank. in AutoCAD | CAD download (1.08 MB) | Bibliocad
Tank. in AutoCAD | CAD download (1.08 MB) | Bibliocad
Sistemas solares fotovoltaicos para casa eficientes para energia limpia
Sistemas solares fotovoltaicos para casa eficientes para energia limpia
the types of storage tanks used in the oil and gas industry are shown here to describe
the types of storage tanks used in the oil and gas industry are shown here to describe
LPG Storage Tank Size Calculation (Excel Sheet)
LPG Storage Tank Size Calculation (Excel Sheet)

The Kennedy-Hanawalt Formula

The Kennedy-Hanawalt formula, often referred to as the K-H formula, is widely used for designing large-diameter, shallow storage tanks. It was developed by William Kennedy and Ernest Hanawalt in the 1930s and has since been adopted by numerous industries.

The K-H formula simplifies the design process by estimating the required wall thickness based on a single equation. It considers several factors, including the tank's diameter, liquid level, and the upward pressure exerted by the liquid.

AD

Applying the K-H Formula

To use the K-H formula, engineers first determine the minimum required wall thickness for a tank of given dimensions. This involves calculating the hoop stress acting on the tank wall and ensuring it does not exceed the material's allowable stress.

a poster explaining how tank storage design impacts safety, loss and emissions in oil & gas
a poster explaining how tank storage design impacts safety, loss and emissions in oil & gas

The formula is typically applied using the following equation: t = (PR) / (SE - 0.6P), where t is the minimum required wall thickness, P is the maximum upward liquid pressure on the tank bottom, R is the tank's internal radius, S is the maximum allowable stress, and E is the joint efficiency factor.

Limitations of the K-H Formula

While the K-H formula offers a simplified approach, it has several limitations. It is predominantly suited for tanks with a height-to-diameter ratio less than 0.5 and assumes the tank is construction-welded without any reinforcement.

AD

Moreover, the K-H formula does not account for wind and snow loads, seismicity, or fatigue design. Therefore, it is typically used as a screening tool or for preliminary design, with the final design being checked against a more comprehensive code, such as API 620 or EN 14015.

EN 14015: European Standard for Storage Tanks

EN 14015 is a European standard that provides design and construction rules for unfired, cylindrical or spherical welded or Lugged steel storage tanks for the modernization or new installations.

The standard considers various design factors, including material properties, design temperatures, and design pressures. It also addresses corrosion protection, anchoring, and support systems.

EN 14015 Design Process

The EN 14015 design process involves several stages. Engineers first determine the tank's dimensions based on the volume to be stored and any site-specific constraints. Next, they select suitable materials and calculate the required wall thickness.

They then calculate the required anchorage and support systems to resist various loads, including wind, snow, and the tank's content. Finally, they design the tank's corrosion protection system and any ancillary equipment, such as nozzling, floating roofs, or internal linings.

EN 14015: Additional Requirements

EN 14015 introduces additional requirements not typically found in API standards or the K-H formula. For instance, it mandates regular inspections during the tank's lifespan, including internal inspections using ropes or remote-operated vehicles.

The standard also provides guidance on site-specific design, such as accounting for uneven foundations, sloping sites, or high seismic activity. Finally, it emphasizes the importance of quality assurance and management systems throughout the tank's lifecycle.

The design of storage tanks is a multifaceted process that demands a solid understanding of design codes, materials science, and structural analysis. With the proliferation of different design codes and standards, engineers must continually stay updated to ensure they select the most appropriate code for a given project. By doing so, they can deliver safe, efficient, and cost-effective storage solutions tailored to their clients' unique needs.

AD